Ozone Library Navigation
General Ozone Generator Information:
Ozone Generator Applications:
New Information from Absolute Ozone to help you save money
|
• Ozone is not stored in bulk on-site
• Catastrophic large-scale release is not likely because generator shutdown stops ozone supply
• Ozone is not explosive or flammable
• leaks are identifiable - repair when they occur
• No reported fatalities from ozone exposure Please. Think safety.
Effects of Ozone Exposure
| Condition |
Ozone Concentration |
| Detectable odor |
0.01 to 0.04 ppmv |
| TLV-TWA 8-hr limit |
0.10 ppmv |
| Headache, shortness of breath |
>0.10 ppmv |
| TLV-STEL 15-min limit |
0.30 ppmv |
| Chest pain, dry cough, lung irritation, severe fatigue |
0.6 - 1.0 ppmv (1 - 2 hrs) |
| Immediately dangerous to life & health |
10.0 ppmv |
| Expected to be fatal |
50 ppmv (30 min) |
| |
Data from “Ozone Manual of Standard Practice”, Workers Compensation Board of British Columbia, 1992 |
For more information Call Toll Free: 1 (877) 486-3761 or Email: Office@AbsoluteOzone.com |