Specifications:
|
|
Product
Characteristics |
|
Product
Flow: 17 SCFH (8-9 LPM) |
|
Standard
Product Pressure: 20 psig |
|
Product
Purity: 93% Nominal |
|
Product
Dew Point: -100°F (-73°C) |
|
Ambient
Operating Conditions |
|
Locate
the oxygen generator in a well-ventilated area that |
|
is
protected from weather elements and remains between |
|
40°F
(4°C) and 112°F (44°C) |
|
Control
Power Requirements |
|
120 V ~
±10%, 50/60 Hz, Single Phase, 4.0 A |
|
220 V ~
±10%, 50/60 Hz, Single Phase, 2.0 A |
|
Typical
Power Consumption (at 93% purity): 350 W |
|
Physical
Connections |
|
Compressed Air Inlet: 1/4" NPT |
|
Product
Gas Outlet: 1/4" NPT/B size oxygen adapter |
|
Certifications and Approvals |
|
NRTL
certified compliance to UL3101.1, CSA, CE |
|
Warranty: 1 Year Parts and Factory Labor* |
|
|
AirSep Reliant
Please click on the image to enlarge
-
Ideal for soil remediation
-
Produces oxygen from compressed air
-
Microprocessor controlled
-
Low operating cost
-
Automatic and unattended operation
-
Easy to install and maintain
|
Specifications:
|
|
Product Characteristics
|
|
Standard Product Flow: 15 SCF/hr1 (0.39
Nm3/hr2) |
|
Standard Product Pressure: 0–50 psig
(5–345 kPa) |
|
Minimum Product Purity: 90%
|
|
Product Dew Point: -100°F (-73°C)
|
|
Ambient Operating Conditions
|
|
Locate the oxygen generator in a
climate-controlled area |
|
that remains between 40°F (4°C) and
100°F (27°C) |
|
Control Power Requirements
|
|
120 V ~ ±10%, 50/60 Hz, Single Phase,
6.0 A |
|
220 V ~ ±10%, 50/60 Hz, Single Phase,
3.0 A |
|
Typical Power Consumption (at 90%
purity): 680 W |
|
Physical Characteristics
|
|
Dimensions (W x D x H): 22.5 x 24.5 x
36.25 in. |
|
(57 x 62 x 92 cm) |
|
Weight: 175 lb. (113.4 kg) |
|
Physical Connections |
|
Product Gas Outlet: 1/4" NPT/B size
oxygen |
|
demand valve |
|
Sound Level: 58 db(A) @ 1 meter, open
field
conditions |
|
Warranty: 1 Year Parts and Factory
Labor* |
|
AirSep AS-A

Please click on the image to enlarge
-
Ideal for soil remediation
-
Perfect match for Atlas 60 ozone
generator
-
Produces oxygen from compressed air
-
Microprocessor controlled
-
Low operating cost
-
Automatic and unattended operation
-
Easy to install and maintain
|
Specifications:
|
|
Product Characteristics
|
|
Product Flow: 10 - 25 SCFH (Factory set to your
specific requirements)
Standard Product Pressure: 1–65 psig
Product
Purity: 93% Nominal
Product Dew Point: -100°F (-73°C)
|
|
Ambient Operating Conditions
|
|
Locate the oxygen generator in a well-ventilated
area that is protected from weather elements and remains between
40°F (4°C) and 112°F (44°C)
|
|
Feed Air Requirements
|
|
Flow Rate: 3.5 - 6 SCFM
|
Clean and Dry "Plant Air" per ISO Specification
5.7.5
Pressure: 90 psig (620 kPa) minimum Temperature: 122°F (50°C)
maximum |
|
Control Power Requirements
|
|
120 V ~ ±10%, 50/60 Hz, Single Phase, 1.5 A 220 V
~ ±10%, 50/60 Hz, Single Phase, 0.75 A Typical Power Consumption (at
93% purity): 180 W
|
|
Physical Connections
|
|
Compressed Air Inlet: ¼" NPT x ¼" NPSM Product Gas
Outlet: ¼" NPT/B size oxygen adapter
|
|
Certifications and Approvals
|
|
NRTL certified compliance to UL3101.1, CSA, CE
|
|
Warranty: 1 Year Parts and Factory Labor*
|
|
AirSep AS-B

Please click on the image to enlarge
-
Ideal for soil remediation
-
Perfect match for Atlas 80 ozone
generator
-
Produces oxygen from compressed air
-
Microprocessor controlled
-
Low operating cost
-
Automatic and unattended operation
-
Easy to install and maintain
|
|
Specifications:
|
|
Product Characteristics
|
|
Product Flow: 30 - 55 SCFH (Factory
set to your specific requirements)
Standard Product Pressure: 1–65
psig
Product Purity: 93% Nominal
Product Dew Point: -100°F (-73°C)
|
|
Ambient Operating Conditions
|
|
Locate the
oxygen generator in a well-ventilated area that is protected from
weather elements and remains between 40°F (4°C) and 112°F (44°C)
|
|
Feed Air
Requirements
|
|
Flow Rate: 11
- 15 SCF
|
|
Clean and Dry "Plant Air" per ISO
Specification 5.7.5
Pressure: 90 psig (620 kPa) minimum
Temperature: 122°F (50°C) maximum
|
|
Control Power Requirements
|
|
120 V ~ ±10%, 50/60 Hz, Single Phase,
1.5 A 220 V ~ ±10%, 50/60 Hz, Single Phase, 0.75 A Typical Power
Consumption (at 93% purity): 180 W
|
|
Physical Connections
|
|
Compressed Air Inlet: ¼" NPT x ¼"
NPSM Product Gas Outlet: ¼" NPT/B size oxygen adapter
|
|
Certifications
and Approvals
|
|
NRTL certified
compliance to UL3101.1, CSA, CE
|
|
Warranty: 1 Year Parts and Factory
Labor*
|
|
|
AirSep AS-D

-
Ideal for soil remediation
-
Perfect match for Magnum ozone
generator
-
Produces oxygen from compressed air
-
Microprocessor controlled
-
Low operating cost
-
Automatic and unattended operation
-
Easy to install and maintain
|
|
Specifications:
|
|
Product Characteristics
|
|
Product Flow: 80 - 90 SCFH (Factory
set to your specific requirements)
Standard Product Pressure: 45
psig
Product Purity: 93% Nominal
Product Dew Point: -100°F (-73°C)
|
|
Ambient Operating Conditions
|
|
Locate the
oxygen generator in a well-ventilated area that is protected from
weather elements and remains between 40°F (4°C) and 112°F (44°C)
|
|
Feed Air
Requirements
|
|
Flow Rate: 16
- 18 SCF
|
|
Clean and Dry "Plant Air" per ISO
Specification 5.7.5
Pressure: 90 psig (620 kPa) minimum
Temperature: 122°F (50°C) maximum
|
|
Control Power Requirements
|
|
120 V ~ ±10%, 50/60 Hz, Single Phase,
1.0 A
220 V ~ ±10%, 50/60 Hz, Single Phase, 0.5 A
Typical Power
Consumption (at 93% purity): 180 W
|
|
Physical Connections
|
|
Compressed Air Inlet: ¼" NPT x
3/8" NPSM Product Gas Outlet: ¼" NPT/B size oxygen adapter
|
|
Certifications
and Approvals
|
|
NRTL certified
compliance to UL3101.1, CSA, CE
|
|
Warranty: 1 Year Parts and Factory
Labor*
|
|
AirSep AS-E
-
Ideal for soil remediation
-
Produces oxygen from compressed air
-
Microprocessor controlled
-
Low operating cost
-
Automatic and unattended operation
-
Easy to install and maintain
|
|
Specifications:
|
|
Product Characteristics
|
|
Product Flow: 165 - 195 SCFH (Factory
set to your specific requirements)
Standard Product Pressure: 45
psig
Product Purity: 93% Nominal
Product Dew Point: -100°F (-73°C)
|
|
Ambient Operating Conditions
|
|
Locate the
oxygen generator in a well-ventilated area that is protected from
weather elements and remains between 40°F (4°C) and 112°F (44°C)
|
|
Feed Air
Requirements
|
|
Flow Rate: 30
- 36 SCF
|
|
Clean and Dry "Plant Air" per ISO
Specification 5.7.5
Pressure: 90 psig (620 kPa) minimum
Temperature: 122°F (50°C) maximum
|
|
Control Power Requirements
|
|
120 V ~ ±10%, 50/60 Hz, Single Phase,
3 A
220 V ~ ±10%, 50/60 Hz, Single Phase, 1 A
|
|
Physical Connections
|
|
Compressed Air Inlet: 1/2" NPT; Product Gas Outlet:
3/8" NPT/B size oxygen adapter
|
|
Certifications
and Approvals
|
|
NRTL certified
compliance to UL3101.1, CSA, CE
|
|
Warranty: 1 Year Parts and Factory
Labor*
|
|
|
AirSep AS-G
-
Produces oxygen from compressed air
-
Microprocessor controlled
-
Low operating cost
-
Automatic and unattended operation
-
Easy to install and maintain
|
|
Specifications:
|
|
Product Characteristics
|
|
Product Flow: 250 - 320 SCFH (Factory
set to your specific requirements)
Standard Product Pressure: 45
psig
Product Purity: 93% Nominal
Product Dew Point: -100°F (-73°C)
|
|
Ambient Operating Conditions
|
|
Locate the
oxygen generator in a well-ventilated area that is protected from
weather elements and remains between 40°F (4°C) and 112°F (44°C)
|
|
Feed Air
Requirements
|
|
Flow Rate: 50
- 65 SCF
|
|
Clean and Dry "Plant Air" per ISO
Specification 5.7.5
Pressure: 90 psig (620 kPa) minimum
Temperature: 122°F (50°C) maximum
|
|
Control Power Requirements
|
|
120 V ~ ±10%, 50/60 Hz, Single Phase,
3 A
220 V ~ ±10%, 50/60 Hz, Single Phase, 1 A
|
|
Physical Connections
|
|
Compressed Air Inlet: 3/4” NPT
Product Gas Outlet: 3/8” NPT
|
|
Certifications
and Approvals
|
|
NRTL certified
compliance to UL3101.1, CSA, CE
|
|
Warranty: 1 Year Parts and Factory
Labor*
|
|

AirSep AS-J
-
Produces oxygen from compressed air
-
Microprocessor controlled
-
Low operating cost
-
Automatic and unattended operation
-
Easy to install and maintain
|
|
Specifications:
|
|
Product Characteristics
|
|
Product Flow: 450 - 600 SCFH (11.83 -
15.77 Nm3/hr)1
1Factory set to your specific requirements.
Standard Product Pressure: 45 psig (3.10 barg)2
2Pressures up to 65 psig (4.48 barg) available. Refer to chart for
air requirement.
Product Purity: 93% Nominal
Product Dew Point: -100°F (-73°C)
|
|
Ambient Operating Conditions
|
|
Locate the
oxygen generator in a well-ventilated area that is protected from
weather elements and remains between 40°F (4°C) and 112°F (44°C)
|
|
Feed Air
Requirements
|
|
Flow Rate: 85
- 115 SCF
|
|
Clean and Dry "Plant Air" per ISO
Specification 5.7.5
Pressure: 90 psig (620 kPa) minimum
Temperature: 122°F (50°C) maximum
|
|
Control Power Requirements
|
|
120 V ~ ±10%, 50/60 Hz, Single Phase,
3 A
220 V ~ ±10%, 50/60 Hz, Single Phase, 1 A
|
|
Physical Connections
|
|
Compressed Air Inlet: 3/4” NPT
Product Gas Outlet: 3/8” NPT
|
|
Certifications
and Approvals
|
|
NRTL certified
compliance to UL3101.1, CSA, CE
|
|
Warranty: 1 Year Parts and Factory
Labor*
|
|

AirSep AS-K
-
Produces oxygen from compressed air
-
Microprocessor controlled
-
Low operating cost
-
Automatic and unattended operation
-
Easy to install and maintain
|
|
Specifications:
|
|
Product Characteristics
|
|
Product Flow: 750 - 900 SCFH (19.72 -
23.66 Nm3/hr)1
1Factory set to your specific requirements.
Standard Product Pressure: 45 psig (3.10 barg)2
2Pressures up to 65 psig (4.48 barg) available. Refer to chart for
air requirement.
Product Purity: 93% Nominal
Product Dew Point: -100°F (-73°C)
|
|
Ambient Operating Conditions
|
|
Locate the
oxygen generator in a well-ventilated area that is protected from
weather elements and remains between 40°F (4°C) and 112°F (44°C)
|
|
Feed Air
Requirements
|
|
Flow Rate: 140
- 155 SCF
|
|
Clean and Dry "Plant Air" per ISO
Specification 5.7.5
Pressure: 90 psig (620 kPa) minimum
Temperature: 122°F (50°C) maximum
|
|
Control Power Requirements
|
|
120 V ~ ±10%, 50/60 Hz, Single Phase,
3 A
220 V ~ ±10%, 50/60 Hz, Single Phase, 1 A
|
|
Physical Connections
|
|
Compressed Air Inlet: 1” NPT
Product Gas Outlet: 3/4” NPT
|
|
Certifications
and Approvals
|
|
NRTL certified
compliance to UL3101.1, CSA, CE
|
|
Warranty: 1 Year Parts and Factory
Labor*
|
|
|
*An unprotected or inadequately ventilated
environment or improper control power may cause damage to the oxygen